• Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com
INC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150p
  • Anasayfa
  • Kurumsal
  • Ürünlerimiz
    • _____
      • SİNYAL İZOLATÖRLERİ VE BARRİERLERİ
      • DEBİ ÖLÇÜMÜ
      • SIVI ANALİZ SİSTEMLERİ
      • KAYDEDİCİLER VE KONTROLÖRLER
      • VANA VE MANİFOLDLAR
      • ENDÜSTRİYEL KAZAN VE BRÜLÖR EKİPMANLARI
      • YÜKSEK SICAKLIK FIRIN KAMERA SİSTEMLERİ
    • _____
      • SICAKLIK TRANSMİTTERLERİ
      • SEVİYE ÖLÇÜMÜ
      • GAZ ANALİZÖRLERİ
      • POZİSYONERLER VE IP ÇEVİRİCİLER
      • FİTTİNGS ELEMANLARI
      • YOĞUNLUK VE KONSANTRASYON ANALİZÖRLERİ
    • _____
      • BASINÇ ÖLÇÜMÜ
      • SICAKLIK ÖLÇÜMÜ
      • GÖSTERGELER
      • AKTÜATÖRLER
      • BASINÇ REGÜLATÖRLERİ VE FİLTRELER
      • BRİX ÖLÇER
  • Temsilciliklerimiz
    • PR Electronics
    • ABB Instrumentation
    • Panam Engineers
    • Fireye Inc.
    • Sensotech
    • Nuova Fima
    • Tercom
    • Flowline
    • Intra Automation
    • ProMtec
    • Delta Kamera Systeme
  • Görseller
  • Blog
  • İletişim
  • Türkçe
Teknik Döküman
TECHNICALDATA
Power supplyvoltage; current:
230/110(115)VAC (50/60Hz); 0.5/1.2A(230/110VAC)

Ignition HT transformers:input, output,weight, dimensions:
–P/N TX-230-8000input: 230 VACat0.5A; output: 8000 VAC, 15 mA, 100% duty cycle
–P/N TX-110-8000input: 110/115 VACat1.2A;output: 8000 VAC, 15 mA, 100% duty cycle
weight, dimensions:1.8kg, LxWxD 107x87x64

Methodof operation:
electrical arc

Ignition controlsignal:
24VDC, max.12A (20A peak)

Availablerod insertionlengthL1:
0.65 ÷ 3.15 m

Rodsand tipsouterdiameter, material:
Ø16 mm, 316 SS

Rods optimal electrical operation parameters:
15-20 mA at 7,500–10,000 V

Rods and tips:operatingtemperature, IPrating, weight:
–P/N HTSS-xxx-J -40°C÷+100°C, IP67 (j. box), +200°C rod tube;L1=0.65 m-0.77 kg
–P/N HTSS-xxx-CEX -40°C÷+80°C, IP66 (cable entry), +200°C rod tube;L1=0.65 m-1.00 kg
–P/N HTSS-xxx-J-CEX -40°C÷+80°C, IP66 (j. box), +200°C rod tube;L1=0.65 m-1.73 kgrods weight adder:approx. 0.44 kg / meter
–Tip P/N HTR-TIPlength 160 mm, 0.16 kg; caution:used on rods lengths L=0.5, 0.6, 0.7 only
–Tip P/NHTR-TIP-Llength 460 mm, 0.32kg
tip operating temperature:+300°C tip continuously, over +1,000°C in flame for short period central Kanthal electrode over +1,000°C continuously

Power packs:
operatingtemperature, IPrating, weight, material:
–P/N HTSS-PP-230/110-40°C÷+65°C, IP66, 6 kg; C. Steel powder-coated or option S. Steel
–P/N HTSS-PP-230/110-CEX-40°C÷+65°C, IP66, 20 kg;Cast Alum.powder-coated or option S. Steel

HVignition single wire cable data:
–P/N HT-CAB-5:type FZ-LSi, OD 7 mm, 15kV, wire 1.0 mm², oper. temp.: -50 +180°C
–P/N HT-CAB -5-CEX: type FZ-LSIekw, shielded, OD 8 mm, 15kV, wire 1.0 mm², oper. temp.: -50 +180°C
–P/N HT-CAB-5 and HT-CAB-5-CEX (5 m working length)weight: 0.37 kg and 0.42.

Flame monitoring (in case of S&S mode used): MBCE-110/230FR flame rod module:
–operation mode: continuous
–functional safety: suitable for installations up to and including SIL2(Exida’s FMEDA report)

Paylaş

Telefon

+90 312 491 05 06
  • Anasayfa
  • Kurumsal
  • Ürünlerimiz
  • Temsilciliklerimiz
  • Görseller
  • Blog
  • İletişim
  • Türkçe
© 2020 INC Endüstriyel Ürünler. All Rights Reserved.
  • No translations available for this page
  • Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com