• Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com
INC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150p
  • Anasayfa
  • Kurumsal
  • Ürünlerimiz
    • _____
      • SİNYAL İZOLATÖRLERİ VE BARRİERLERİ
      • DEBİ ÖLÇÜMÜ
      • SIVI ANALİZ SİSTEMLERİ
      • KAYDEDİCİLER VE KONTROLÖRLER
      • VANA VE MANİFOLDLAR
      • ENDÜSTRİYEL KAZAN VE BRÜLÖR EKİPMANLARI
      • YÜKSEK SICAKLIK FIRIN KAMERA SİSTEMLERİ
    • _____
      • SICAKLIK TRANSMİTTERLERİ
      • SEVİYE ÖLÇÜMÜ
      • GAZ ANALİZÖRLERİ
      • POZİSYONERLER VE IP ÇEVİRİCİLER
      • FİTTİNGS ELEMANLARI
      • YOĞUNLUK VE KONSANTRASYON ANALİZÖRLERİ
    • _____
      • BASINÇ ÖLÇÜMÜ
      • SICAKLIK ÖLÇÜMÜ
      • GÖSTERGELER
      • AKTÜATÖRLER
      • BASINÇ REGÜLATÖRLERİ VE FİLTRELER
      • BRİX ÖLÇER
  • Temsilciliklerimiz
    • PR Electronics
    • ABB Instrumentation
    • Panam Engineers
    • Fireye Inc.
    • Sensotech
    • Nuova Fima
    • Tercom
    • Flowline
    • Intra Automation
    • ProMtec
    • Delta Kamera Systeme
  • Blog
  • İletişim
  • İngilizce
  • Türkçe
Teknik Döküman
SPECIFICATIONS

MECHANICAL, BASIC MODELS (-1QD) and FIBER OPTIC MODELS (-2QD):
Housing Material:
Cast aluminum with gray polyester powder coat.

Ingress Protection:
IP66 with 0.4 joule impact rating
.
Scanner Weight:
5.90 lbs. (2.69kg)

Mounting Flange:
P/N 60-2919-1, 1" NPT female pipe mount with 3/8” NPT female cooling air
connection. Contains an integral heat-insulating female thread insert.

ENVIRONMENTAL:
Temperature Rating:
-40°F/-40°C to 150°F/+65°C ambient; -40°F/-40°C to 180 °F/82°C scanner internal temperature.

Humidity:
0% to 95% relative humidity, non-condensing

COOLING/ PURGE AIR REQUIREMENTS:
Source:
Clean, dry, cool

Volume: 4 SCFM (113 l/min) at 3/8" threaded mounting flange, or 1 inch
“Y” fitting, mounted on scanner sight pipe.

Pressure:
Adequate to overcome furnace or windbox

ELECTRICAL:
Input Power:
24 Vdc nominal, supply current 200 mA

Electrical Connection:
8-PIN quick-disconnect

Relay Outputs:
FLAME RELAY, SPST (N.O.)
FAULT RELAY, SPST (N.C.)

Contact Rating:
Minimum: 10 mA @ 5 Vdc
Maximum: 2 A @ 30 Vdc, 2 A @ 230 Vac (Resistive load)

Analog Output:
Optically isolated 4 to 20mA dc current referenced to 24 Vdc common,
maximum connected load: 750 Ohms.

Status Indication:
Multiple LED indication for flame signal strength, flame relay,
ready, target, background select and fault codes

MECHANICAL, CEX MODELS:
Housing Material:
Cast aluminum with gray polyester powder coat.

Housing Rating:
Ex II 2 G/D rated, ATEX certified

Scanner Weight:
9.5 lbs (4.3kg)

Mounting Flange:
P/N 129-168-1, 1" NPT female pipe mount flange with

OPTICAL:
UV models - 295 to 340 nanometers
IR models - 830 to 1100 nanometers
CABLE SPECIFICATION:
Specification: P/N 59-546:

Multi-core, 8 conductor (color coded), with foil wrap and overall braided
shield. PLTC-ER rating
Eight #18 AWG
Temperature Rating: -40° F to +221°F (-40°C to +105°C)
Cable Jacket: PVC
Nominal O.D. 0.44" (11.2 mm)
Maximum O.D. 0.48" (12.2 mm)