• Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com
INC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150p
  • Anasayfa
  • Kurumsal
  • Ürünlerimiz
    • _____
      • SİNYAL İZOLATÖRLERİ VE BARRİERLERİ
      • DEBİ ÖLÇÜMÜ
      • SIVI ANALİZ SİSTEMLERİ
      • KAYDEDİCİLER VE KONTROLÖRLER
      • VANA VE MANİFOLDLAR
      • ENDÜSTRİYEL KAZAN VE BRÜLÖR EKİPMANLARI
      • YÜKSEK SICAKLIK FIRIN KAMERA SİSTEMLERİ
    • _____
      • SICAKLIK TRANSMİTTERLERİ
      • SEVİYE ÖLÇÜMÜ
      • GAZ ANALİZÖRLERİ
      • POZİSYONERLER VE IP ÇEVİRİCİLER
      • FİTTİNGS ELEMANLARI
      • YOĞUNLUK VE KONSANTRASYON ANALİZÖRLERİ
    • _____
      • BASINÇ ÖLÇÜMÜ
      • SICAKLIK ÖLÇÜMÜ
      • GÖSTERGELER
      • AKTÜATÖRLER
      • BASINÇ REGÜLATÖRLERİ VE FİLTRELER
      • BRİX ÖLÇER
  • Temsilciliklerimiz
    • PR Electronics
    • ABB Instrumentation
    • Panam Engineers
    • Fireye Inc.
    • Sensotech
    • Nuova Fima
    • Tercom
    • Flowline
    • Intra Automation
    • ProMtec
    • Delta Kamera Systeme
  • Görseller
  • Blog
  • İletişim
  • Türkçe
9113A-Kullanım Klavuzu
9113A-Teknik Döküman
Temperature / mA converter
Input for RTD, TC and mA
Active / passive mA output via the same two terminals
1 or 2 channels
Can be supplied separately or installed on power rail, PR type 9400
SIL 2-certified via Full Assessment

Advanced features
Configuration and monitoring by way of detachable display front (PR 4511/4501); process calibration and signal simulation.
Copying of the configuration from one device to others of the same type via the display front.
TC inputs can use either the internal CJC or a terminal with a built-in Pt100 sensor (PR 5910, channel 1 / PR 5913, channel 2) for higher accuracy.
Advanced monitoring of internal communication and stored data.
SIL 2 functionality is optional and must be activated in a menu point.

Application
The device can be mounted in and receive signals from non-classified area and zone 2.
Conversion and scaling of temperature (Pt, Ni and TC) and active current signals.
9113A has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508.
Technical characteristics
1 green and 2 red front LEDs indicate operation status and malfunction.
2.6 kVAC galvanic isolation between input, output and supply.

Mounting
The devices can be mounted vertically or horizontally without distance between neighbouring units.
Paylaş

Telefon

+90 312 491 05 06
  • Anasayfa
  • Kurumsal
  • Ürünlerimiz
  • Temsilciliklerimiz
  • Görseller
  • Blog
  • İletişim
  • Türkçe
© 2020 INC Endüstriyel Ürünler. All Rights Reserved.
  • No translations available for this page
  • Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com