• Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com
INC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150p
  • Anasayfa
  • Kurumsal
  • Ürünlerimiz
    • _____
      • SİNYAL İZOLATÖRLERİ VE BARRİERLERİ
      • DEBİ ÖLÇÜMÜ
      • SIVI ANALİZ SİSTEMLERİ
      • KAYDEDİCİLER VE KONTROLÖRLER
      • VANA VE MANİFOLDLAR
      • ENDÜSTRİYEL KAZAN VE BRÜLÖR EKİPMANLARI
      • YÜKSEK SICAKLIK FIRIN KAMERA SİSTEMLERİ
    • _____
      • SICAKLIK TRANSMİTTERLERİ
      • SEVİYE ÖLÇÜMÜ
      • GAZ ANALİZÖRLERİ
      • POZİSYONERLER VE IP ÇEVİRİCİLER
      • FİTTİNGS ELEMANLARI
      • YOĞUNLUK VE KONSANTRASYON ANALİZÖRLERİ
    • _____
      • BASINÇ ÖLÇÜMÜ
      • SICAKLIK ÖLÇÜMÜ
      • GÖSTERGELER
      • AKTÜATÖRLER
      • BASINÇ REGÜLATÖRLERİ VE FİLTRELER
      • BRİX ÖLÇER
  • Temsilciliklerimiz
    • PR Electronics
    • ABB Instrumentation
    • Panam Engineers
    • Fireye Inc.
    • Sensotech
    • Nuova Fima
    • Tercom
    • Flowline
    • Intra Automation
    • ProMtec
    • Delta Kamera Systeme
  • Görseller
  • Blog
  • İletişim
  • Türkçe
5225A-Kullanım Klavuzu
5225A-Teknik Döküman
Programmable f/I-f/f converter
Pulse conditioning
Frequency generator
Concurrent f/I and f/f function
Analog current and voltage output
PNP / NPN output, optional relays
Programmable by PC and Loop Link

Advanced features
The 5225 transmitter can be configured with a standard PC and the Loop Link communications unit, or delivered fully configured.

Application
The f/I function performs frequency to current and voltage conversion.
The f/f function can be used for pulse division or multiplication and as a buffer collecting fast pulse trains.
The concurrent f/I and f/f functions enable a scaled digital output signal in conjunction with the analog output.
The frequency generator function is used as e.g. a time base or clock generator.
Input and supply polarity reversal protection.
Programmable digital outputs including NPN, PNP or relay options.

Technical characteristics
4 front LEDs, indicating f in active inputs (not NPN), Dig.out.1 (NPN or relay 1) and Dig.out 2 (relay 2) outputs, and a NAMUR input error signal.
Analog current output can be configured to any current within 0...20 mA range.
Voltage output range is selectable between 0...10 VDC and 0...1 VDC by use of internal jumpers.
Input range:
Frequency: 0...20,000 Hz
Sensor types: NAMUR, tacho, NPN, PNP, TTL, S0
Output range:
Current and voltage output: 0...20 mA / 0...10 V
Relay outputs: 0...20 Hz
NPN and PNP output as f/f: 0...1000 Hz
NPN and PNP output as generator: 0...20,000 Hz
Paylaş

Telefon

+90 312 491 05 06
  • Anasayfa
  • Kurumsal
  • Ürünlerimiz
  • Temsilciliklerimiz
  • Görseller
  • Blog
  • İletişim
  • Türkçe
© 2020 INC Endüstriyel Ürünler. All Rights Reserved.
  • No translations available for this page
  • Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com