• Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com
INC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150p
  • Anasayfa
  • Kurumsal
  • Ürünlerimiz
    • _____
      • SİNYAL İZOLATÖRLERİ VE BARRİERLERİ
      • DEBİ ÖLÇÜMÜ
      • SIVI ANALİZ SİSTEMLERİ
      • KAYDEDİCİLER VE KONTROLÖRLER
      • VANA VE MANİFOLDLAR
      • ENDÜSTRİYEL KAZAN VE BRÜLÖR EKİPMANLARI
      • YÜKSEK SICAKLIK FIRIN KAMERA SİSTEMLERİ
    • _____
      • SICAKLIK TRANSMİTTERLERİ
      • SEVİYE ÖLÇÜMÜ
      • GAZ ANALİZÖRLERİ
      • POZİSYONERLER VE IP ÇEVİRİCİLER
      • FİTTİNGS ELEMANLARI
      • YOĞUNLUK VE KONSANTRASYON ANALİZÖRLERİ
    • _____
      • BASINÇ ÖLÇÜMÜ
      • SICAKLIK ÖLÇÜMÜ
      • GÖSTERGELER
      • AKTÜATÖRLER
      • BASINÇ REGÜLATÖRLERİ VE FİLTRELER
      • BRİX ÖLÇER
  • Temsilciliklerimiz
    • PR Electronics
    • ABB Instrumentation
    • Panam Engineers
    • Fireye Inc.
    • Sensotech
    • Nuova Fima
    • Tercom
    • Flowline
    • Intra Automation
    • ProMtec
    • Delta Kamera Systeme
  • Görseller
  • Blog
  • İletişim
  • Türkçe
5223B-Kullanım Klavuzu
5223B-Teknik Döküman
Programmable f/I-f/f converter
Pulse calculator / frequency generator
Galvanic isolation
ATEX I.S. version
Analog current and voltage output
PNP / NPN output, optional relays
Universal supply

Advanced features
The 5223 transmitter can be configured with a standard PC and the Loop Link communications unit, or delivered fully configured.

Application
The f/I function performs frequency to current and voltage conversion.
The f/f function can be used for pulse division or multiplication and as a buffer collecting fast pulse trains.
A scale factor may be entered in all functions. Using both digital inputs, pulse addition or subtraction are possible.
The frequency generator function is used as e.g. a time base or clock generator.
Input and supply polarity reversal protection.
Current and voltage output signals galvanically separated from the supply and the inputs.
Programmable digital outputs including NPN, PNP or relay options.
ATEX units have input for mechanical contact and NAMUR inductive proximity sensor.

Technical characteristics
5 front LEDs, indicating f1 and f2 active inputs (not NPN), Dig.out.1 and 2 active outputs, and a programmable error signal.
Analog current output can be configured to any current within 0...20 mA range.
Voltage output range is selectable between 0...10 VDC and 0...1 VDC by use of internal jumpers.
Input range:
Frequency: 0...20,000 Hz
Sensor types: NAMUR, tacho, NPN, PNP, TTL, S0
Output range:
Current and voltage output: 0...20 mA / 0...10 V
Relay outputs: 0...20 Hz
Paylaş

Telefon

+90 312 491 05 06
  • Anasayfa
  • Kurumsal
  • Ürünlerimiz
  • Temsilciliklerimiz
  • Görseller
  • Blog
  • İletişim
  • Türkçe
© 2020 INC Endüstriyel Ürünler. All Rights Reserved.
  • No translations available for this page
  • Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com