• Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com
INC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150p
  • Anasayfa
  • Kurumsal
  • Ürünlerimiz
    • _____
      • SİNYAL İZOLATÖRLERİ VE BARRİERLERİ
      • DEBİ ÖLÇÜMÜ
      • SIVI ANALİZ SİSTEMLERİ
      • KAYDEDİCİLER VE KONTROLÖRLER
      • VANA VE MANİFOLDLAR
      • ENDÜSTRİYEL KAZAN VE BRÜLÖR EKİPMANLARI
      • YÜKSEK SICAKLIK FIRIN KAMERA SİSTEMLERİ
    • _____
      • SICAKLIK TRANSMİTTERLERİ
      • SEVİYE ÖLÇÜMÜ
      • GAZ ANALİZÖRLERİ
      • POZİSYONERLER VE IP ÇEVİRİCİLER
      • FİTTİNGS ELEMANLARI
      • YOĞUNLUK VE KONSANTRASYON ANALİZÖRLERİ
    • _____
      • BASINÇ ÖLÇÜMÜ
      • SICAKLIK ÖLÇÜMÜ
      • GÖSTERGELER
      • AKTÜATÖRLER
      • BASINÇ REGÜLATÖRLERİ VE FİLTRELER
      • BRİX ÖLÇER
  • Temsilciliklerimiz
    • PR Electronics
    • ABB Instrumentation
    • Panam Engineers
    • Fireye Inc.
    • Sensotech
    • Nuova Fima
    • Tercom
    • Flowline
    • Intra Automation
    • ProMtec
    • Delta Kamera Systeme
  • Görseller
  • Blog
  • İletişim
  • Türkçe
5116A-Kullanım Klavuzu
5116A-Teknik Döküman
Programmable transmitter
Input for RTD, TC, mV, Ohm, potentiometer, mA and V
2-wire supply > 16.5 V
Bipolar voltage input
Output for current, voltage and 2 relays
Universal supply by AC or DC

Application
Linearized, electronic temperature measurement with RTD or TC sensor.
Conversion of linear resistance variation to a standard analog current / voltage signal, i.e. from solenoids and butterfly valves or linear movements with attached potentiometer.
Power supply and signal isolator for 2-wire transmitters.
Process control with 2 potential-free relay contacts which can be configured for advanced functions.
Galvanic separation of analog signals and measurement of floating signals.

Technical characteristics
Within a few seconds the user can program PR5116A to suit the specific application.
By way of the front push-button the input can be calibrated to the exact span of the process. Zero drift on the process signal can be adjusted by a single press of the front buttton.
A green front LED indicates normal operation and malfunction. A yellow LED is ON for each active output relay.
Continuous check of vital stored data for safety reasons.
3-port 3.75 kVAC galvanic isolation.

Mounting / installation
Mounted vertically or horizontally on a DIN rail. As the devices can be mounted without any distance between neighboring units, up to 42 devices can be mounted per meter.
Paylaş

Telefon

+90 312 491 05 06
  • Anasayfa
  • Kurumsal
  • Ürünlerimiz
  • Temsilciliklerimiz
  • Görseller
  • Blog
  • İletişim
  • Türkçe
© 2020 INC Endüstriyel Ürünler. All Rights Reserved.
  • No translations available for this page
  • Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com