• Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com
INC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150p
  • Anasayfa
  • Kurumsal
  • Ürünlerimiz
    • —–
      • SİNYAL İZOLATÖRLERİ VE BARRİERLERİ
      • DEBİ ÖLÇÜMÜ
      • SIVI ANALİZ SİSTEMLERİ
      • KAYDEDİCİLER VE KONTROLÖRLER
      • VANA VE MANİFOLDLAR
      • ENDÜSTRİYEL KAZAN VE BRÜLÖR EKİPMANLARI
      • YÜKSEK SICAKLIK FIRIN KAMERA SİSTEMLERİ
    • —–
      • SICAKLIK TRANSMİTTERLERİ
      • SEVİYE ÖLÇÜMÜ
      • GAZ ANALİZÖRLERİ
      • POZİSYONERLER VE IP ÇEVİRİCİLER
      • FİTTİNGS ELEMANLARI
      • YOĞUNLUK VE KONSANTRASYON ANALİZÖRLERİ
    • —–
      • BASINÇ ÖLÇÜMÜ
      • SICAKLIK ÖLÇÜMÜ
      • GÖSTERGELER
      • AKÜTATÖRLER
      • BASINÇ REGÜLATÖRLERİ VE FİLTRELER
      • BRİX ÖLÇER
  • Temsilciliklerimiz
    • PR ELECTRONICS
    • ABB
    • PANAM ENGINEERS
    • FIREYE INC
    • SENSOTECH
    • NUOVA FIMA
    • TERCOM
    • FLOWLINE
    • INTRA AUTOMATION
    • PROMTEC
    • DELTA KAMERA SYSTEME
  • Görseller
  • Faydalı Bilgiler
  • İletişim
3186-Kullanım Klavuzu
3186-Teknik Döküman
2-wire transmitter isolator / current isolator
1 or 2 channel 2-wire transmitter isolator / current isolator
1:1 conversion in the range 3.5...23 mA
Low channel voltage drop and fast response time < 5 ms
Excellent accuracy, better than 0.05%
Slimline 6 mm housing

Application
3186A is a 1:1 output loop-powered 2-wire transmitter isolator that excites and measures passive input signals.
3186B is a 1:1 output loop-powered 2-wire current isolator that measures active input signals.
A very competitive choice in terms of both price and technology for galvanic isolation.
Provides surge suppression and protects control systems from transients and noise.
3186 eliminates ground loops and can be used for measuring floating signals.
The device can be mounted in Safe area or in Zone 2 and Cl. 1 Div 2. area.

Technical characteristics
3186 is powered by the host loop voltage.
Wide supply range from 6...35 V.
Low input to output voltage drop typ. 2.5 V (3186A).
Low input drop ≤ 3 V (3186B), even when no loop power is applied to the output terminals.
Excellent conversion accuracy, better than 0.05% in the range 3.8…20.5 mA.
Signal range is 3.5...23 mA which means that 3186 is NAMUR NE43 compliant.
Inputs and outputs are floating and galvanically separated.
High galvanic isolation of 2.5 kVAC.
Fast response time < 5 ms.
Excellent signal/noise ratio > 60 dB.

Mounting / installation
DIN rail mounting with up to 330 channels per meter.
Extended operating temperature range from -25...+70°C.