• Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com
INC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150p
  • Homepage
  • About Us
  • Products
    • _____
      • SIGNAL ISOLATORS AND BARRIERS
      • FLOW MEASUREMENT
      • LIQUID ANALYSIS SYSTEMS
      • RECORDERS AND CONTROLLERS
      • VALVES AND MANIFOLDS
      • INDUSTRIAL BOILER AND BURNER EQUIPMENT
      • HIGH TEMPERATURE OVEN CAMERA SYSTEMS
    • _____
      • TEMPERATURE TRANSMITTERS
      • LEVEL MEASUREMENT
      • GAS ANALYZERS
      • POSITIONERS AND IP DIALERS
      • FITTIGS ELEMENTS
      • DENSITY AND CONCENTRATION ANALYZERS
    • _____
      • PRESSURE MEASUREMENT
      • TEMPERATURE MEASUREMENT
      • INDICATORS
      • ACTUATORS
      • PRESSURE REGULATORS AND FILTERS
      • BRIX METER
  • Representatives
    • PR Electronics
    • ABB Instrumentation
    • Panam Engineers
    • Fireye Inc.
    • Sensotech
    • Nuova Fima
    • Tercom
    • Flowline
    • Intra Automation
    • ProMtec
    • Delta Kamera Systeme
  • Images
  • Blog
  • Contact Us
  • English
  • Turkish
9202A-Kullanım Klavuzu
9202A-Teknik Döküman
Pulse isolator
Interface for NAMUR sensors and switches
Extended self-diagnostics and detection of cable fault
1 or 2 channels
Can be supplied separately or installed on power rail, PR type 9400
SIL 2-certified via Full Assessment

Advanced features
Configuration and monitoring by way of detachable display front (PR 4511/4501).
Selection of direct or inverted function for each channel via PR 4511/4501.
Advanced monitoring of internal communication and stored data.
Optional redundant supply via power rail and/ or separate supply.
SIL 2 functionality is optional and must be activated in a menu point.

Application
The device can be mounted in and receive signals from non-classified area and zone 2.
Pulse isolator for transmission of signals from NAMUR sensors and mechanical switches.
Monitoring of error events and cable breakage via the individual status relay and/or a collective electronic signal via the power rail.
The 9202A has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508.

Technical characteristics
1 green and 2 yellow/red front LEDs indicate operation status and malfunction.
2.6 kVAC galvanic isolation between input, output and supply.

Mounting
The devices can be mounted vertically or horizontally without distance between neighbouring units.
Paylaş

Telefon

+90 312 491 05 06
  • Homepage
  • About Us
  • Products
  • Representatives
  • Images
  • Blog
  • Contact Us
  • English
  • Turkish
© 2020 INC Endüstriyel Ürünler. All Rights Reserved.
  • English
  • Turkish
  • Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com