• Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com
INC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150p
  • Homepage
  • About Us
  • Products
    • _____
      • SIGNAL ISOLATORS AND BARRIERS
      • FLOW MEASUREMENT
      • LIQUID ANALYSIS SYSTEMS
      • RECORDERS AND CONTROLLERS
      • VALVES AND MANIFOLDS
      • INDUSTRIAL BOILER AND BURNER EQUIPMENT
      • HIGH TEMPERATURE OVEN CAMERA SYSTEMS
    • _____
      • TEMPERATURE TRANSMITTERS
      • LEVEL MEASUREMENT
      • GAS ANALYZERS
      • POSITIONERS AND IP DIALERS
      • FITTIGS ELEMENTS
      • DENSITY AND CONCENTRATION ANALYZERS
    • _____
      • PRESSURE MEASUREMENT
      • TEMPERATURE MEASUREMENT
      • INDICATORS
      • ACTUATORS
      • PRESSURE REGULATORS AND FILTERS
      • BRIX METER
  • Representatives
    • PR Electronics
    • ABB Instrumentation
    • Panam Engineers
    • Fireye Inc.
    • Sensotech
    • Nuova Fima
    • Tercom
    • Flowline
    • Intra Automation
    • ProMtec
    • Delta Kamera Systeme
  • Images
  • Blog
  • Contact Us
  • English
  • Turkish
9116B-EMP-Kullanım Klavuzu
9116B-EMP-Teknik Döküman
Universal converter, EMPHASIS assessed
Input for RTD, TC, Ohm, potentiometer, mA and V
Supply for 2-wire transmitters
Active / passive mA output and relay output
EMPHASIS assessed instrument for nuclear industry
SIL 2-certified via Full Assessment

Advanced features
Configuration and monitoring by way of detachable display front (PR4511/4501); process calibration, signal and relay simulation.
Advanced relay configuration, e.g. setpoint, window, delay, sensor error indication and power monitoring.
Copying of the configuration from one device to others of the same type via PR4511/4501.
Reduced Uo Ex data < 8.3 V for active input signals.
TC inputs with internal CJC or external CJC for higher accuracy.
Active / passive mA output via the same two terminals.

Application
9116B-EMP can be mounted in the safe area and in zone 2 / cl. 1 div. 2 and receive signals from zone 0, 1, 2 and zone 20, 21, 22 including M1 / Class I/II/III, Div. 1, Gr. A-G.
Conversion and scaling of temperature, voltage, potentiometer and linear resistance signals.
Power supply and signal isolator for 2-wire transmitters.
Monitoring of error events and cable breakage via the individual status relay and/or a collective electronic signal via the power rail.
The 9116B-EMP has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508.
Suitable for the use in systems up to Performance Level “d” according to ISO-13849.

Technical characteristics
1 green and 1 red front LED indicate operation status and malfunction. 1 yellow LED indicates relay status.
2.6 kVAC galvanic isolation between input, output and supply.
Can be supplied separately or installed on power rail, PR type 9400.

Mounting
The devices can be mounted vertically or horizontally without distance between neighbouring units.