• Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com
INC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150p
  • Homepage
  • About Us
  • Products
    • _____
      • SIGNAL ISOLATORS AND BARRIERS
      • FLOW MEASUREMENT
      • LIQUID ANALYSIS SYSTEMS
      • RECORDERS AND CONTROLLERS
      • VALVES AND MANIFOLDS
      • INDUSTRIAL BOILER AND BURNER EQUIPMENT
      • HIGH TEMPERATURE OVEN CAMERA SYSTEMS
    • _____
      • TEMPERATURE TRANSMITTERS
      • LEVEL MEASUREMENT
      • GAS ANALYZERS
      • POSITIONERS AND IP DIALERS
      • FITTIGS ELEMENTS
      • DENSITY AND CONCENTRATION ANALYZERS
    • _____
      • PRESSURE MEASUREMENT
      • TEMPERATURE MEASUREMENT
      • INDICATORS
      • ACTUATORS
      • PRESSURE REGULATORS AND FILTERS
      • BRIX METER
  • Representatives
    • PR Electronics
    • ABB Instrumentation
    • Panam Engineers
    • Fireye Inc.
    • Sensotech
    • Nuova Fima
    • Tercom
    • Flowline
    • Intra Automation
    • ProMtec
    • Delta Kamera Systeme
  • Images
  • Blog
  • Contact Us
  • English
  • Turkish
5350B-Kullanma-Kılavuzu
5350B-Teknik-Döküman
Profibus PA / Foundation Fieldbus transmitter
PROFIBUS PA ver. 3.0
FOUNDATION Fieldbus ver. ITK 4.6
Automatic switch between protocols
FISCO-certified
Basic or LAS capability with F.F.

Application
Linearized temperature measurement with RTD or TC sensor.
Difference, average or redundancy temperature measurement with RTD or TC sensor.
Linear resistance, potentiometer and bipolar mV measurement.

Technical characteristics
Bus transmitter with both PROFIBUS PA and FOUNDATION Fieldbus communication. A unique switch function ensures automatic shift between the two protocols.
Set-up for PROFIBUS PA can be done via Siemens Simatic® PDM®, ABB Melody / Harmony and Metso DNA software and for FOUNDATION Fieldbus via Emerson DeltaV, Yokogawa CS 1000 / CS 3000, ABB Melody / Harmony and Honeywell Experion software.
The simulation mode function can be activated by way of a magnet.
Polarity-independent bus connection.
24 bit A/D converter ensures high resolution.
PROFIBUS PA function blocks:
2 analog.
FOUNDATION Fieldbus function blocks:
2 analog and 1 PID.
FOUNDATION Fieldbus capability:
Basic or LAS.

Mounting / installation
For DIN form B sensor head mounting.
Paylaş

Telefon

+90 312 491 05 06
  • Homepage
  • About Us
  • Products
  • Representatives
  • Images
  • Blog
  • Contact Us
  • English
  • Turkish
© 2020 INC Endüstriyel Ürünler. All Rights Reserved.
  • English
  • Turkish
  • Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com