• Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com
INC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150p
  • Homepage
  • About Us
  • Products
    • _____
      • SIGNAL ISOLATORS AND BARRIERS
      • FLOW MEASUREMENT
      • LIQUID ANALYSIS SYSTEMS
      • RECORDERS AND CONTROLLERS
      • VALVES AND MANIFOLDS
      • INDUSTRIAL BOILER AND BURNER EQUIPMENT
      • HIGH TEMPERATURE OVEN CAMERA SYSTEMS
    • _____
      • TEMPERATURE TRANSMITTERS
      • LEVEL MEASUREMENT
      • GAS ANALYZERS
      • POSITIONERS AND IP DIALERS
      • FITTIGS ELEMENTS
      • DENSITY AND CONCENTRATION ANALYZERS
    • _____
      • PRESSURE MEASUREMENT
      • TEMPERATURE MEASUREMENT
      • INDICATORS
      • ACTUATORS
      • PRESSURE REGULATORS AND FILTERS
      • BRIX METER
  • Representatives
    • PR Electronics
    • ABB Instrumentation
    • Panam Engineers
    • Fireye Inc.
    • Sensotech
    • Nuova Fima
    • Tercom
    • Flowline
    • Intra Automation
    • ProMtec
    • Delta Kamera Systeme
  • Images
  • Blog
  • Contact Us
  • English
  • Turkish
5131B-Kullanım Klavuzu
5131B-Teknik Döküman
2-wire programmable transmitter
Input for RTD, TC, mV, linear resistance, mA, and V
3.75 kVAC galvanic isolation
4...20 mA loop output
1- and 2-channel versions
ATEX Ex / I.S. version
DIN rail mounting

Advanced features
The 5131 transmitter can be configured with a standard PC and the Loop Link communications unit.

Application
Independent channel jumper selectable inputs for current/voltage or temperature.
Current input programmable in range the 0...100 mA and voltage inputs in the range 0...250 VDC.
Linearized, electronic temperature measurement with RTD or TC sensor.
Conversion of linear resistance variation to a standard analog current / voltage signal, for example from solenoids and butterfly valves or linear movements with attached potentiometer.
4- or 3-wire connection with automatic cable compensation or 2-wire connection with programmable cable compensation.
Configurable sensor error detection including NAMUR NE43.

Technical characteristics
The 2-channel version has full galvanic isolation between the channels.
Separation of circuits in PELV/SELV installations.
I.S. barrier for temperature sensors, potentiometers and current / voltage signals.