• Size Nasıl Yardımcı Olabiliriz?
  • +90 312 491 05 06
  • info@incendustri.com
INC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150pINC-Logo-400X150p
  • Homepage
  • About Us
  • Products
    • _____
      • SIGNAL ISOLATORS AND BARRIERS
      • FLOW MEASUREMENT
      • LIQUID ANALYSIS SYSTEMS
      • RECORDERS AND CONTROLLERS
      • VALVES AND MANIFOLDS
      • INDUSTRIAL BOILER AND BURNER EQUIPMENT
      • HIGH TEMPERATURE OVEN CAMERA SYSTEMS
    • _____
      • TEMPERATURE TRANSMITTERS
      • LEVEL MEASUREMENT
      • GAS ANALYZERS
      • POSITIONERS AND IP DIALERS
      • FITTIGS ELEMENTS
      • DENSITY AND CONCENTRATION ANALYZERS
    • _____
      • PRESSURE MEASUREMENT
      • TEMPERATURE MEASUREMENT
      • INDICATORS
      • ACTUATORS
      • PRESSURE REGULATORS AND FILTERS
      • BRIX METER
  • Representatives
    • PR Electronics
    • ABB Instrumentation
    • Panam Engineers
    • Fireye Inc.
    • Sensotech
    • Nuova Fima
    • Tercom
    • Flowline
    • Intra Automation
    • ProMtec
    • Delta Kamera Systeme
  • Images
  • Blog
  • Contact Us
  • English
  • Turkish
5115A-Kullanım Klavuzu
5115A-Teknik Döküman
Signal calculator
Redundancy measurement with 2 input signals
Signal calculator with the four arithmetical operations
Duplication of the input signal
Input for RTD, Ohm, TC, mV, mA, and V
Universal supply by AC or DC

Application
Redundancy measurement of temperature by means of two sensors, where the secondary sensor takes over the measurement when a sensor error occurs on the primary sensor.
Duplication of the input signal, e.g. from a temperature sensor or an analog process signal to two separate analog outputs.
Signal calculator with four arithmetical operations: Addition, subtraction, multiplication and division.
Example: Differential measurement:
(Input 1 * K1) - (Input 2 * K2) + K4
Example: Average measurement:
(Input 1 * 0.5) + (Input 2 * 0.5) + K4
Example: Different functions on the outputs:
Output 1 = input 1 - input 2, and Output 2 = input 1 + input 2
Power supply for 2-wire transmitters.

Technical characteristics
Within a few seconds the user can program PR5115A to a selected application using the configuration program PReset.
A green front LED indicates normal operation, sensor error on each sensor, and functional error.
Continuous check of vital stored data for safety reasons.
5-port 3.75 kVAC galvanic isolation.

Mounting / installation
Mounted vertically or horizontally on a DIN rail. As the devices can be mounted without any distance between neighboring units, up to 42 devices can be mounted per meter.